Wellbore Schematic

DGWS Wellbore Schematic Example


Injection Rate
Estimated Injection Rate 100 BWPD*                                (5.6spm slip speed, 86″ stroke)
Maximum Injection Rate 240 BWPD*                                (12.4spm slip speed, 86″ stroke)
Minimum Injection Rate 11 BWPD*                                   (1.5spm slip speed, 60″ stroke)

Operating at 24 hours per day

Injection Pressure
Maximum Downhole Injection
Pressure                                                                              1819 psig
RFI Conditions
Runtime                                                                                100%
Surface Casing Pressure                                                      85 psig
Bottomhole Temperature                                                      130oF
Upstroke Damping Factor                                                     0.150
Downstroke Damping Factor                                                0.160
Ambient Temperature                                                           60oF
Wellhead Temperature                                                         103
Fluid Level from Surface                                                      2764′
Flowing Bottomhole Pressure                                              91 psig
DHI Plunger Diameter                                                          1.497″ (1 ½” Insert Pump)
Pump Intake Depth                                                               2785′
Pump Liquid Fillage                                                              95 to 99%
Pump Intake Pressure                                                          100psig
Pump Plunger Friction                                                          85lbf
DSB Friction                                                                         235lbf
DHI Plunger Length                                                             4′
Plunger Clearance                                                               0.003
Valve Rod Size                                                                    ¾”
Downhole Stuffing Box                                                        ¾” UTEX
Maximum Pump Fluid Load                                               3038 lbf (at 200 BWPD)
Maximum T.V. Load                                                           6659 lbf (at 200 BWPD)
Maximum S.V. Load                                                           3621 lbf (at 200 BWPD)
Pump Barrel Length                                                           16′
Plunger Space off Bottom                                                  0.50″
Fluids
Water Cut                                                                        100.00%
Oil Density                                                                       No Oil
Water Density                                                                 1.01 Sp. Gr. H2O
Gas Density                                                                    0.70 Sp.Gr.Air
Solution GOR                                                                 0 scf/STBO
Tubing Fluid Density                                                      1.00 Sp. Gr. H2O
Casing Fluid Density                                                     0.83 Sp. Gr. H2O
Bubble Point Pressure                                                 -15.0 psig
Surface Pumping Unit
Surface Unit Type                                                       Conventional
API Description                                                           C-228-246-86
Rotation Direction                                                       Clockwise
Maximum Stroke                                                         Length 86″
Electric Motor
Motor Type                                                             Oilfield Nema D
Motor Size                                                              20 hp
Voltage                                                                   480 V
Phase                                                                     3 Phase

At Injecting  200 BWPD
Cyclic Load Factor                                                 1.323 (at 200 BWPD)
Average Prime Mover Slip                                     4.7% (at 200 BWPD)
Maximum Prime Mover Slip                                   13.7% (at 200 BWPD)
Minimum Prime Mover Slip                                    -0.5% (at 200 BWPD)
Motor Power Loading                                            78.0% (at 200 BWPD)
It also contains common side-effects that http://appalachianmagazine.com/category/history/old-ways-memories/page/6/ discount price on viagra are related withimpotence. There are hardly such medicines in the market which hold a really less value but the effects are way better than 100 s of pills. tablets viagra For these reasons, plus the fact that I check content free viagra 100mg was incredibly shy with girls right into my mid-twenties, certainly did not help matters either. The medical experts explain that levitra generic usa 100mg has been approved by the medicinal analyzers of Food & Drug Association (FDA).
Variable Frequency Drive
Size                                                                         20hp
Voltage                                                                   480V
Minimum Frequency                                              7 Hz
Maximum Frequency                                             80 Hz
Phase Three Phase
Features                                                                Pump Off Controller, Timer, Clock,Communications
Tubing (2800′)
2 3/8″ EUE 8RD J55 Upset
4.70 lbs/ft
Tubing ID                                                               1.995″
Tubing OD                                                             2.375″
Production Casing (3000′)
5 ½” J55 15.50lbs/ft
Casing OD                                                              5.500″
Casing ID                                                                4.950″
Rod String
Rod Service Factor                                                1.00 (New Rods)
Surface Stuffing Box Friction                                 10.0 lbf
Polished Rod Diameter                                          1 ¼”
Maximum Polished Rod Load                                9895 lbf (at 200 BWPD)
Minimum Polished Rod Load                                 461 lbf (at 200 BWPD)
Buoyant Rod Weight                                              3621 lbf (at 200 BWPD)
Surface Card Power                                              10.6 hp (at 200 BWPD)
Pump Card Power                                                 7.1 hp (at 200 BWPD)
Polished Rod Length                                              20.0′
Rod Type                      Size        Top Stress (psi)             Bottom Stress (psi)            Loading
API Grade D Steel       0.875″     17350max, 1720min.    10803max, -1245min.         55.8%
API Grade D Steel       0.750″     15145max, -1254min.   5335max, -2446min            56%

Rod Type                    Size          Weight           Length              Percent of Taper
API Grade D Steel      0.875″      2.224lb/ft       1159′                   41.6%
API Grade D Steel     0.750″      1.634 lbs/ft      1626′                 58.4%


Rate Analysis at Injecting 200BWPD

Pump Liquid Rate                                  202.5 BWPD (90.9%)
Pump Gas Rate                                     10.7 BWPD (4.8%)
Tubing Stretch Losses                           0.0 BWPD (0.0%)
Plunger Slippage Losses                       9.7 BWPD (4.3%)
Pump Total Rate                                    222.8 BWPD (100.0%)
Pump Liquid Efficiency                          90.0%
Injecting Liquid Efficiency                      83.3%

Maximum Plunger Velocity                    5.8 ft/s (at 200 BWPD)

Net Area of the Top of the

Plunger that the Pressure is
Acting on                                               0.0092ft2
Maximum Instantaneous

Injection rate at 200BWPD:                   0.0533ft3/s (23.94gal/min or 821 BPD)


Energy Analysis at Injecting 200BWPD

Liquid Hydraulic Power                                5.9hp (40.6%)
Gas Compression Power                             0.1hp (0.5%)
Pump Losses                                               1.1hp (7.8%)
Rodstring Losses                                         3.5hp (24.0%)
Surface Unit Losses                                    1.2hp (8.2%)
Motor Losses                                               2.8hp (19.1%)
Consumed Electrical Power                        14.6hp (100.0%)
Generated Electrical Power                        0.0hp
System Efficiency                                       40.6%